Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 9: 1523-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26346758

RESUMO

PURPOSE: To describe the use of a ruler to increase the accuracy and customization of Lester Jones tube placement. MATERIALS AND METHODS: This was a review of 92 patients who underwent minimally invasive conjunctivodacryocystorhinostomy using this instrument. RESULTS: The success rate was 100%, with an average operating time of 15 minutes. In nine patients, late migration of the Jones tube into the nasal cavity required a secondary intervention, with successful Jones tube repositioning. In five cases, obstruction of the tube opening was caused by conjunctival overgrowth. CONCLUSION: The millimetric ruler engraved in the sleeve of the trocar allows measuring and placing a personalized tube for each patient.

2.
Indian J Ophthalmol ; 62(6): 741-3, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25005212

RESUMO

Delleman syndrome is an unusual entity, characterized by ocular cysts or microphthalmia, focal dermal anomalies and cerebral malformations. In the following article, we carry out a review of the disease and we present the case of a patient with microphthalmos and palpebral coloboma. As we could not put orbital expanders at an early stage, we performed reconstructive surgery.


Assuntos
Anormalidades Múltiplas , Cistos do Sistema Nervoso Central/diagnóstico , Vermis Cerebelar/patologia , Anormalidades do Olho/diagnóstico , Pálpebras/anormalidades , Dedos/anormalidades , Microftalmia/diagnóstico , Anormalidades da Pele/diagnóstico , Blefaroplastia , Pálpebras/cirurgia , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética , Masculino
3.
Ophthalmic Plast Reconstr Surg ; 28(3): 219-20, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22460678

RESUMO

PURPOSE: To report the authors' experience using a regular crochet hook for removing blue periocular eyelid veins. METHODS: This article describes a new surgical procedure. Twenty-one procedures were performed in 15 patients who underwent removal of blue periocular lower eyelid veins with the implementation of a regular crochet hook. RESULTS: There was no clinical evidence of treatment failure during the subsequent 12 months, nor did any new veins appear. CONCLUSIONS: Periocular vein removal with a Crochet hook is safe and successful. It can augment blepharoplasty results.


Assuntos
Pálpebras/irrigação sanguínea , Procedimentos Cirúrgicos Oftalmológicos , Varizes/cirurgia , Procedimentos Cirúrgicos Vasculares/instrumentação , Procedimentos Cirúrgicos Ambulatórios , Pálpebras/cirurgia , Humanos , Cirurgia Plástica , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...